Implementations - Populate Distributer Checksum for custom distributions

Introduction

This document will provide reference steps for how to update checksums and packages for the Bold Distributer.

Process

  • Navigate to the distributer directory
    • %\Program Files (x86)\Bold Technologies\Manitou\Distributer\
  • Locate the intended Patch folder or Package Folder numbered sub-folder
    • Patch Folder - Numbered patches for Manitou -Distributes with Update to Latest Patch command
    • Package Folder - Contains Numbered patch folders - Distributes with Send Package Number # command
  • Place the intended files into the appropriate folder
  • Locate the appropriate distlist.txt or packagelist.txt file and open with Notepad++
  • Locate the intended Patch or Package Folder Number in the list.
  • Build the Item number using the following breakdown
    • Destination Path - %MANITOU%
    • File Name - FULL-FILENAME.EXE
    • Control Characters - Reference Guide Below
    • Checksum - Numeric Value
    • EXAMPLE: %MANITOU%, 5975-AVIGILON--VCC_DRIVER_AVIGILON7_SETUP.EXE, 011, 2458700769, , ,

image.png

  • In this example. the 4 Files being pushed in patch 29 will need to have Checksums Generated as they are not currently known.
    • DistList Package Entries needing Checksum Generation:
    • %MANITOU%, MANITOU.EXE, 001, , ,
      %MANITOU%, 5975-AVIGILON--VCC_DRIVER_AVIGILON7_SETUP.EXE, 011, , ,
      %MANITOU%, EXPERIMENTAL-5975-AVIGILON--VCC_DRIVER_AVIGILON5_SETUP.EXE, 011, , ,
      %MANITOU%, 5975-AVIGILON--VCC_BASE_SETUP.EXE, 011, , ,
  • Launch the Distributer Commander from the Desktop Shortcut
  • From the File Menu, select Admin > Populate File Checksums
  • When Prompted select Update CRC's

image.png

  • Once the Distributer commander has finished the Checksum Population, reload the Distlist.txt file to verify the new entries were created.
    • Example of actual values generated:
      • %MANITOU%, MANITOU.EXE, 001, 323618604, , ,
      • %MANITOU%, 5975-AVIGILON--VCC_DRIVER_AVIGILON7_SETUP.EXE, 011, 2458700769, , ,
      • %MANITOU%, EXPERIMENTAL-5975-AVIGILON--VCC_DRIVER_AVIGILON5_SETUP.EXE, 011, 435723210, , ,
      • %MANITOU%, 5975-AVIGILON--VCC_BASE_SETUP.EXE, 011, 2752369692, , ,
  • Open the Logger and select the Distributer Checkbox
  • Perform a test push to the local server or a non-critical workstation to verify the package/patch will update the appropriate files
  • Updated Files and Dislist are now updated and ready for normal use.


Was this article helpful?
Thank you for your feedback!
User Icon

Thank you! Your comment has been submitted for approval.