Numera Libris Guide

Introduction

Numera Libris is a GPS mobile device that provides alarm messages and plots the data on a map in the “Libris” portal. It does not contain any client information. However, when integrated with Manitou using the Bold UniversalConnector, it works in tandem to provide a great deal of information for the operator/agent responding to the alarm.

For more information on the Numera Libris product, please visit http://numera.com/libris/.

Purpose

The purpose of this document is to provide guidance in integration between Numera Libris and Manitou/ManitouNEO. This is NOT a step by step instructional manual.

Manitou/ManitouNEO Integration

Requirements

  • Bold MediaGateway/UnivesalConnector with a FILE connector type
  • Bold POSTlistener configured in the C:\inetpub directory of an IIS system with ports 80 or 443 exposed.
  • Bold XML Receiver configured for the MediaGateway
  • Manitou Transmitter Type for Event Monitoring system (if using optional TwoWayPLUS, configure the desired signals as Audio Capable) with Raw Programming enabled

Options

  • TwoWayPLUS (specifically InstantConnect)
  • BoldTrak GPS (to see latitude/longitude coordinates in Manitou – including historical data)
  • Bold XML Receiver configured for the GPS MediaGateway
  • Manitou Transmitter Type for GPS system with Raw Programming enabled

Numera Libris Account Information

Numera Libris will setup two server platforms for customers: (1) for “staging,” and, (2) for “production.” If you are using the POSTlistener configured for Numera Libris, the Public IP will be included in the “Whitelisted” portion of the CSHTML file.

Nortek uses a PUT command rather than a POST command. If not using the POSTlistener provided, be prepared to configure the web application to accept PUT commands.

Set the app pool for the SMSlistener to be the following:

Nortek will need the following information:

Numera Libris / Manitou Event Code Translations Using HTTP POST/PUT

Reported Condition

Manitou Interpretation (Description)

Event Code

Normal

Panic 

PA

MedicalDevice

Medical Device Alert (Libris+ only)

PA1

Fall 

Medical Alarm

MA 

Classify

Fall Possible

MT

GPSLoc 

Location Update - GPS

UX1 

NetworkLoc

Location Update - Network

UX2

BatteryLow

Battery Low

*L 

ON 

Device Powered On

*ON 

Activation 

 Device Commissioned (Device was activated) 

*A 

Deactivation 

Device Decommissioned (Deactivated) 

NC 

FailActivation

Device Commissioning Failed

NT

NetworkChange

Network Availability Change

*Z

LowActivityAlarm 

System Inactivity

*LG 

LongChargeAlarm

System Inactivity (In charger)

*LO 

ChargeChange

Charger Change (On/Off charging cradle)

*M

*Note – Not all events from Numera Libris are transmitted to the Bold UniversalConnector through the API. Additionally, many of these events are defaulted to “Alarm = No.” Please ensure that any events you desire to have presented to an operator are modified in the Transmitter Type Event Programming.

Nortek/Numera Libris API Raw Events & Descriptions

The following is an excerpt from the Nortek API document:

Event Type

Displays As

Description

LocationFix

Location update

A Location fix (satellite or network) was obtained

Normal

Call

User-initiated phone call from a button press

ON

Powered on

The device turned on or started after a reboot

Classify

Classify

Event created when analyzing activity for a fall

Note

Notes updated

A Patient note was updated

Status

Status

Status log entry

Debug

Debug

Debug log entry

ChargeChange

Charge status

Indicates the state of charging

NetworkChange

Network

Network availability change

Fall

Fall Assistance Call

Fall detected and call initiated

Logfile

Unknown

A request to download logs

BatteryLow

Low Battery Alert

Device has crossed the critical threshold of charge

Activation

Device Activation

Device was activated

FailActivation

Device Fail Activation

The activation failed

Deactivation

Device Deactivated

Device de-activated in UI or through API

MagCalibration

Magnetometer Calibration

Device was re-calibrated based on device's location

LowActivityAlarm

Low Activity Alarm

User has not had significant movement for the duration configured

LongChargeAlarm

Long Charge Alarm

Device left in charger too long

MedicalDevice

Medical Device Alert

Generated as part of Libris+ events

Files

NumeraPutListener.zip

Was this article helpful?